Lowenstein PrismaLab Bipap

Lowenstein PrismaLab Bipap

188000.0 INR/Unit

Product Details:

  • Warranty 1 Year
  • Application Hospital
  • Material Plastic
  • Condition New
  • Portable Yes
  • Operating Type Automatic
  • Dimension (L*W*H) 170 x 135 x 180 Millimeter (mm)
  • Click to view more
X

Lowenstein PrismaLab Bipap Price And Quantity

  • 1 Unit
  • 188000.0 INR/Unit

Lowenstein PrismaLab Bipap Product Specifications

  • 1.4 Kilograms (kg)
  • Yes
  • New
  • 1 Year
  • Plastic
  • Automatic
  • Hospital
  • Black
  • 170 x 135 x 180 Millimeter (mm)

Lowenstein PrismaLab Bipap Trade Information

  • Cash Advance (CA), Cash in Advance (CID), Cheque
  • 10 Unit Per Month
  • 7 Days
  • Asia
  • All India

Product Description

Lowenstein PrismaLab Bipap offers all modes and attributes required for titration in a single device.

Lowenstein PrismaLab Bipap Features:

  • Modes: CPAP, APAP, AcSV, S, autoS, S/T, autoS/T, T, aPCV
  • Continued therapy and soft pressure transitions at change of mode during the night
  • Continuous check of mask fit, automatic mask recognition and mask test
  • High resolution therapy data for up to 14 days and detailed statistics for 366 days
  • Therapy software prismaTS for data analysis and remote control
  • With SD card and USB port
  • Telemedicine connection via modem for prisma CLOUD
  • Eight clearly identified analog signals for PSG feed
  • Intelligient humidification without extra sensors provided by smartAQUAcontrol (with use of
    prismaAQUA)
  • Comfort functions such as autoSTART-STOP and softSTART
  • Heated breathing tube prismaHYBERNITE
  • Easy-to-use accessories

Lowenstein PrismaLab Bipap Specs:

Parameter Value
Modes CPAP, APAP, AcSV, S, autoS, S/T,
autoS/T, T, aPCV
Mean sound pressure level/Operation ISO 80601-2-70 about 26.5 dB(A) at 10 hPa
CPAP/APAP operating pressure range 4 to 20 hPa
BILevel operating pressure range 4 to 30 hPa
AcSV operating pressure range 4 to 30 hPa
Relative inspiration time: Ti/Tset 25% to 67%
Trigger auto or can be set at 3 levels
Pressure increase speed can be set at three levels
Back up frequency auto, 0 bpm to 35 bpm
Pressure accuracy <20 hPa 0.6 hPa, 20 hPa 0.8 hPa
Highest flow as per ISO 80601-2-70, modes Bilevel and AcSV,
without humidifier
4.0 hPa 235 l/min
10.5 hPa 225 l/min
17.0 hPa 215 l/min
23.5 hPa 200 l/min
25.0 hPa 195 l/min
30.0 hPa 190 l/min
Stability of dynamic pressure
(short-term accuracy) at 10 breaths/min as per ISO 17510-1:2007
with 22-mm breathing tube
7.0 hPa p 0.24 hPa
10.0 hPa p 0.28 hPa
13.5 hPa p 0.30 hPa
20.0 hPa p 0.40 hPa
Dimensions (W x H x D) 170 x 135 x 180 mm
Weight about 1.4 kg
System interface 12 V DC max. 10 VA
Alarms leaks, disconnection (tube), apnea, low minute volume, low tidal volume

Lowenstein PrismaLab Bipap Brochure:

Lowenstein PrismaLab Bipap Box Contents:

  • PrismaLab Device
  • Hose Pipe
  • Filters
  • Manuals
  • Bag


Automatic Operation for Optimal Care

The Lowenstein PrismaLab Bipap features fully automatic controls that adjust pressure settings as needed. This innovation ensures patients consistently receive the optimal level of respiratory support without the need for continuous manual intervention, improving both comfort and medical outcomes.


Designed for Mobility and Convenience

Weighing only 1.4 kg and equipped with a compact form factor, this device is perfect for rapid deployment and flexible use within hospitals and clinics. Its lightweight design and durable plastic construction make it easy to transport and handle in dynamic medical environments.

FAQ's of Lowenstein PrismaLab Bipap:


Q: How is the Lowenstein PrismaLab Bipap operated?

A: This device runs automatically, adjusting pressure and settings based on patient needs, ensuring seamless and effective respiratory support without constant manual adjustments.

Q: What are the benefits of the PrismaLab Bipap's portable design?

A: Due to its lightweight (1.4 kg) and compact size, the PrismaLab Bipap is easily transportable, making it suitable for use in various hospital departments or for moving between patients quickly.

Q: When should the PrismaLab Bipap be used in a hospital setting?

A: The device is ideally employed when patients require non-invasive ventilation support, such as in cases of respiratory distress, COPD exacerbations, or other conditions needing BiPAP therapy.

Q: Where can the PrismaLab Bipap be acquired in India?

A: The device is available through authorized distributors, suppliers, and traders across India, ensuring ready access for hospitals and healthcare providers.

Q: What is the process for setting up the PrismaLab Bipap?

A: Setup is straightforward; simply connect the device to a power source and patient interface. Once powered on, it will automatically adjust settings for optimal performance.

Q: What is the warranty coverage for this device?

A: The PrismaLab Bipap comes with a one-year warranty, covering any manufacturing defects or malfunctions during normal hospital usage.

Q: How does using the PrismaLab Bipap benefit hospital operations?

A: By providing reliable automatic ventilation in a portable, durable form, the device streamlines patient care, enhances workflow efficiency, and improves patient outcomes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Care Device' category



Back to top