Contec SP950 Precise Infusion Syringe Pump

Contec SP950 Precise Infusion Syringe Pump

19500.0 INR/Piece

Product Details:

  • Storage Instructions Cool & Dry Place
  • Size Standard
  • Condition New
  • Wall Mounted No
  • Use hospital
  • Feature Good Quality
  • Portable Yes
  • Click to view more
X

Contec SP950 Precise Infusion Syringe Pump Price And Quantity

  • 1 Unit
  • 19500.0 INR/Piece

Contec SP950 Precise Infusion Syringe Pump Product Specifications

  • Plastic
  • No
  • hospital
  • Standard
  • Good Quality
  • Cool & Dry Place
  • Yes
  • 1 year
  • Syringe Infusion Pump
  • New

Contec SP950 Precise Infusion Syringe Pump Trade Information

  • 10 Unit Per Week
  • 7 Days
  • Asia
  • All India

Product Description

Description

Contec SP950 Precise Infusion Syringe Pump Description
SP950 is a syringe pump for medical use, and it adopts microcomputer system and microelectronic technology, features in high-intelligence and high-safety. LCD can display each parameter in real-time, with multi-function alarm, and alarm with visual, auditory and character prompt. It takes the advantages of easy operation, steady work, high accuracy and checking the syringe specification automatically. And now, it has been widely applied in each vein injection in hospitals for clinical nursing, such as ICU, CCU, neonatology, obstetrics, veterinary and gynecology, pediatrics, internal medicine, surgery, operating room, emergency room.
Contec SP950 Precise Infusion Syringe Pump Features:
  • Infusion rate and total volume can be set by user.
  • Alarms for infusion pipe occlusion, syringe fall-off, communication abnormal, low battery.
  • Bright, alarm volume and range of pressure alarm are adjustable.
  • Quick feed function, convenient for supplying medicine quickly and instantaneously.
  • Enter KVO mode after infusion completed.
  • The system will give prompt signal when there is no operation at power-on state.
  • Built-in rechargeable battery provides such functions as auto-switch power supply and auto-charge.
  • Display parameters with large screen, and give prompt information with visual, auditory and character signal, which is convenient for medical persons to operate.
  • The device can equipped with disposable syringe (CNS), and accuracy can be ensured by adjusting parameters.
Contec SP950 Precise Infusion Syringe Pump Performance:
  • Specification requirement for syringe: 10ml/20ml/30ml/50ml (CNS)
  • Infusion rate:
    • 10ml 0.1ml/h-100ml/h
    • 20ml 0.1ml/h-200ml/h
    • 30ml 0.1ml/h-300ml/h
    • 50ml 0.1ml/h-500ml/h
  • Rate of quick feed:
    • 10ml 100ml/h
    • 20ml 200ml/h
    • 30ml 300ml/h
    • 50ml 500ml/h
  • Accumulated volume display: 0ml-999.9ml
  • Accuracy: 3%
  • Pressure range for occlusion alarm: Three grades are adjustable:
    • Low: 40KPa 16KPa
    • Middle: 70KPa 30KPa
    • High: 100KPa 35KPa
  • KVO rate: 0.1ml/h5ml/h, adjustable
  • Safety classification: Class equipment, internally powered type BF
  • Alarm function: At non-operated state Near empty Empty, enter KVO mode Syringe fall-off Occlusion Pressure failure Motor failure Low battery Communication abnormal
  • Maximal power consumption: 20VA30VA, the device can continuously work for at least two hours with the injection rate of 5ml/h or 500ml/h after fully charged.
  • Power supply: AC100240V 50/60Hz
  • Battery: rechargeable lithium battery, 7.4V, 3500mAh
  • Working environment: Temperature: +540; Atmospheric pressure: 860hPa1060h; Relative humidity: 20%90%; no strong vibration and no corrosive gas.
  • Storage environment: Temperature: -20+55; Relative humidity: 90%, no condensation; No corrosive gas and well-ventilated
Contec SP950 Precise Infusion Syringe Pump Accessories
  • Syringe Pump
  • A bracket
  • A power cord
  • A user manual
  • Two fuses
Contec SP950 Precise Infusion Syringe Pump Physical characteristic
  • Dimension: 310mm*140mm*135mm(LWH)
  • Weight: 1.7kg


Advanced Precision for Hospital Applications

The Contec SP950 Syringe Infusion Pump is meticulously crafted for delivering exact doses of medication within hospital environments. Its advanced features guarantee precision, which is crucial for patient safety during infusions. Lightweight and portable, this pump is easy to transport from room to room, seamlessly supporting medical staff during patient care.


Portability and User-Friendly Operation

Designed with ergonomics in mind, the SP950 is easy to handle and move between patient bedsides. Despite its compact nature, it does not require wall mounting and can be stationed conveniently where needed. Intuitive controls and a clear display contribute to straightforward operation, reducing the learning curve for healthcare professionals.


Warranty and Reliable Support

Purchasers of the Contec SP950 benefit from a comprehensive one-year warranty that ensures dependable performance and peace of mind. Distributed by trusted suppliers and traders in India, the product is readily available and supported by responsive customer service. Proper storage in a cool, dry place helps maintain its quality and longevity.

FAQ's of Contec SP950 Precise Infusion Syringe Pump:


Q: How do I use the Contec SP950 Precise Infusion Syringe Pump in a hospital setting?

A: To use the Contec SP950, place it on a stable surface near the patient, insert the prescribed syringe, set the infusion parameters on the display, and begin the process. Always ensure the device is operated by trained medical personnel for accurate results.

Q: What are the main benefits of using this syringe infusion pump?

A: The primary benefits include highly accurate medication delivery, portability for easy movement within the hospital, reliable construction from good quality plastic, and a user-friendly interface that streamlines operation for healthcare teams.

Q: Where should the Contec SP950 be stored when not in use?

A: For best performance and longevity, store the pump in a cool, dry place away from direct sunlight or moisture. Proper storage helps preserve both its functional and material quality.

Q: When should the pump be serviced or inspected?

A: Routine inspections should be conducted according to hospital protocols, and the device should be serviced annually or immediately if any performance issue arises. The one-year warranty provides added assurance during the first year of use.

Q: What is the process to set up the infusion parameters on this device?

A: After loading the appropriate syringe, use the control panel to input the desired flow rate and dosage. Refer to the user manual for detailed guidance to ensure settings match the physician's orders. Confirm the settings before starting the infusion.

Q: Who distributes and supplies the Contec SP950 in India?

A: The Contec SP950 is distributed, supplied, and traded by authorized dealers in India. For purchase or support, contact your nearest medical equipment supplier or the official distributor network.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Hospital Equipment' category



Back to top